Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Int. arch. otorhinolaryngol. (Impr.) ; 18(3): 311-315, Jul-Sep/2014.
Artigo em Inglês | LILACS | ID: lil-720854

RESUMO

Introduction: Benign idiopathic tonsillar hypertrophy (HBI) may affect a child's quality of life and sleep. Several studies have sought to relate the clinical features of HBI with the infectious and/or immunologic changes that occur. Objective: To increase the knowledge of the etiology of HBI. Data Synthesis: From 2012 to 2013 we conducted a retrospective observational study of 101 children with HBI who underwent tonsillectomies at Ambulatory ENT General Hospital of the East Zone of São Paulo City, a region with a poor socioeconomic population. Preoperative serologic results were available to confirm mononucleosis, cytomegalovirus, anti-streptolysin O (ASLO) and immunoglobulins. The mean patient age was 5.8 years (55% male, 45% female). Using the Mann-Whitney U test, we identified significant gender differences in the parameters of immunoglobulins (Ig) M (IgM), IgA, and IgE. Forty-seven percent of the patients had increased ASLO levels, and 37% had increased IgE levels. Conclusion: An evaluation of a patient's serologic parameters and laboratory results may be relevant to the etiology and prevention of HBI. Based on the results obtained from the study sample, the identification of etiologic agents and causative factors remain a public health challenge that affects the quality of life of children...


Assuntos
Humanos , Lactente , Pré-Escolar , Criança , Sistema Imunitário , Imunoglobulinas , Tonsila Palatina , Brasil , Estudo Observacional , Estudos Retrospectivos
2.
Arq. bras. cardiol ; 100(2): 105-113, fev. 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-667950

RESUMO

Apesar de avanços nos últimos anos relacionados à prevenção e a tratamento, muitas são as vidas perdidas anualmente no Brasil relacionado à parada cardíaca e a eventos cardiovasculares em geral. O Suporte Básico de Vida envolve o atendimento às emergências cardiovasculares principalmente em ambiente pré-hospitalar, enfatizando reconhecimento e realização precoces das manobras de ressuscitação cardiopulmonar com foco na realização de compressões torácicas de boa qualidade, assim como na rápida desfibrilação, por meio da implementação dos programas de acesso público à desfibrilação. Esses aspectos são de fundamental importância e podem fazer diferença no desfecho dos casos como sobrevida hospitalar sem sequelas neurológicas. O início precoce do Suporte Avançado de Vida em Cardiologia também possui papel essencial, mantendo, durante todo o atendimento, a qualidade das compressões torácicas, adequado manejo da via aérea, tratamento específico dos diferentes ritmos de parada, desfibrilação, avaliação e tratamento das possíveis causas. Mais recentemente dá-se ênfase a cuidados pós-ressuscitação, visando reduzir a mortalidade por meio do reconhecimento precoce e tratamento da síndrome pós-parada cardíaca. A hipotermia terapêutica tem demonstrado melhora significativa da lesão neurológica e deve ser realizada em indivíduos comatosos pós-parada cardíaca. Para os médicos que trabalham na emergência ou unidade de terapia intensiva é de grande importância o aperfeiçoamento no tratamento desses pacientes por meio de treinamentos específicos, possibilitando maiores chances de sucesso e maior sobrevida.


Despite advances related to the prevention and treatment in the past few years, many lives are lost to cardiac arrest and cardiovascular events in general in Brazil every year. Basic Life Support involves cardiovascular emergency treatment mainly in the pre-hospital environment, with emphasis on the early recognition and delivery of cardiopulmonary resuscitation maneuvers focused on high-quality thoracic compressions and rapid defibrillation by means of the implementation of public access-to-defibrillation programs. These aspects are of the utmost importance and may make the difference on the patient's outcomes, such as on hospital survival with no permanent neurological damage. Early initiation of the Advanced Cardiology Life Support also plays an essential role by keeping the quality of thoracic compressions; adequate airway management; specific treatment for the different arrest rhythms; defibrillation; and assessment and treatment of the possible causes during all the assistance. More recently, emphasis has been given to post-resuscitation care, with the purpose of reducing mortality by means of early recognition and treatment of the post-cardiac arrest syndrome. Therapeutic hypothermia has provided significant improvement of neurological damage and should be performed in comatose individuals post-cardiac arrest. For physicians working in the emergency department or intensive care unit, it is extremely important to improve the treatment given to these patients by means of specific training, thus giving them the chance of higher success and of better survival rates.


Assuntos
Adulto , Humanos , Reanimação Cardiopulmonar/métodos , Parada Cardíaca/terapia , Brasil , Desfibriladores , Serviços Médicos de Emergência , Parada Cardíaca Extra-Hospitalar/terapia , Respiração Artificial/métodos , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia
3.
Rev. Soc. Bras. Clín. Méd ; 10(3)maio-jun. 2012.
Artigo em Português | LILACS | ID: lil-621483

RESUMO

JUSTIFICATIVA E OBJETIVOS: Dispositivos como o metrônomo tem demonstrado aumentar a qualidade da reanimação cardiopulmonar (RCP). O objetivo deste estudo foi avaliar a frequência e a profundidade das compressões torácicas (CT) realizadas com e sem o auxílio do metrônomo.MÉTODO: Estudo prospectivo com 44 estudantes de medicina do 1º ano que foram avaliados imediatamente após o curso "Heartsaver DEA". Foi utilizado metrônomo durante o curso,na frequência de 100 por minuto, a fim de auxiliar as CT. Os estudantes realizaram um minuto de CT utilizando o manequim AmbuMan Prolife, parte sem o auxílio do metrônomo (Grupo A) e a outra parte com o auxílio do dispositivo (Grupo B), que permaneceu na frequência de 100 por minuto. Cada avaliação foi filmada e a análise das compressões foi realizada por um instrutor que desconhecia cada grupo. RESULTADOS: A média de idade e a porcentagem do sexo masculino no Grupo A e no Grupo B foram de 20,7 ± 3,5 versus 22,5± 1,9 (p = 0,004) e 45,4% versus 54,6% (p = 0,763), respectivamente. Durante um minuto de compressões torácicas, para os Grupos A e B, a média da frequência foi de 110,3 ± 14,2 versus103,6 ± 9,6, respectivamente (p = 0,37) e a média da porcentagem de compressões com profundidade adequada foi de 39,6% ± 34,7 versus 87,4% ± 21,7, respectivamente (p < 0,001). CONCLUSÃO: O uso do metrônomo durante o treinamento foi efetivo, demonstrado pela frequência correta obtida em ambos os grupos. A profundidade das compressões foi melhor no grupo que utilizou o metrônomo, talvez pelo fato dos estudantes concentrarem maior atenção na profundidade das compressões já que o dispositivo auxiliava na sua frequência.


BACKGROUND AND OBJECTIVES: Devices such as metronome have demonstrated to increase the quality of cardiopulmonary resuscitation (CPR). The objective was evaluating the frequency and depth of chest compressions (CC) performed with and without the aid of the metronome.METHOD: This prospective study involving 44 medical students coursing the first year, were evaluated immediately after the "Heartsaver AED" course. During the training, a metronome was used to guide the compressions frequency (100 per minute). The students performed CC during one minute, both using AmbuMan Prolife manikins, a group without metronome (Group A) and another group with metronome (Group B) guidance with "tock" prompts for compressions, at rate of 100 per minute. Each session was filmed and analysis of the compressions was performed by an instructor without knowledge of each group. RESULTS: The average age and percentage of male gender of Group A and Group B was 20.7 ± 3.5 vs. 22.5 ± 1.9 (p = 0.004) and 45.4% vs. 54.6% (p = 0.763), respectively. During 1 min of CC, considering Group A and Group B, the average rate of compressions was 110.3 ± 14.2 vs. 103.6 ± 9.6, respectively (p= 0.37) and the average percentage of correct depth compression was 39.6% ± 34.7 vs. 87.4% ± 21.7, respectively (p < 0.001). CONCLUSION: Using the metronome during training was effective, demonstrated by the frequency of correct CC in both groups. The greatest depth of CC in the group with metronome may be related to less concern with the frequency due to the presence of the stimulus sound and greater focus on appropriate depth of compressions.


Assuntos
Humanos , Masculino , Feminino , Adulto , Parada Cardíaca , Massagem Cardíaca , Reanimação Cardiopulmonar
4.
Rev. Soc. Bras. Clín. Méd ; 10(2)mar.-abr. 2012.
Artigo em Português | LILACS | ID: lil-621466

RESUMO

JUSTIFICATIVA E OBJETIVOS: A reanimação cardiopulmonar (RCP) somente com compressões torácicas (CT) tem sido amplamente discutida nos últimos anos, principalmente quando realizadas por leigos que testemunham vítimas de parada cardiorrespiratória (PCR). O objetivo desse estudo foi avaliar a qualidade das CT realizadas por leigos antes e após curso "Familiares e Amigos: RCP a Qualquer Hora®". MÉTODO: Participaram do estudo 73 indivíduos que não tinham conhecimento prévio sobre RCP. O estudo foi dividido em três etapas. Na primeira, foi solicitado ao voluntário que realizasse dois minutos de CT, da maneira que julgasse correta, em um manequim que registra tal habilidade. A seguir, o voluntário realizou o curso proposto e, por último, o participante executou novamente dois minutos de CT, utilizando o mesmo manequim da primeira etapa. RESULTADOS: A média de idade dos participantes foi de 20,2 ± 2,9 anos, 26% do sexo masculino. Antes e após o curso, durante dois minutos de CT, os seguintes parâmetros revelaram diferença significativa: a média do número total de compressões (166 versus 198, p = 0,0001), a frequência (89 versus 99 compressões/minuto, p = 0,0055) e a porcentagem de posição correta das mãos (51% versus 87%, p < 0,0001). Já a porcentagem de CT com profundidade adequada foi de 20% antes e de 27% após o curso, não revelando diferença significativa, p = 0,0580. CONCLUSÃO: A qualidade das CT melhorou significativamente após treinamento de RCP. A profundidade das CT ainda é insuficiente mesmo após o treinamento o que enfatiza a necessidade de dispositivos que forneçam um feedback durante a realizaçãoda RCP.


BACKGROUND AND OBJECTIVES: Hands-only cardiopulmonary resuscitation (CPR) has been widely studied and discusse din recent years, especially when performed by lay people who witnessed cardiopulmonary arrest. The objective of this study was to assess the quality of chest compressions (CCs) performed by lay people before and after the course "Family andFriends CPR Anytime®". METHOD: We evaluated 73 individuals who had no prior knowledge about CPR. The study was divided into three steps. At first, the volunteer was asked to conduct two minutes of CCs, as he/she deems proper, on a mannequin that records such skill. Then the volunteer made the course. Finally, the participant performed again two minutes of CCs using the same dummy first step. RESULTS: The mean age of participants was 20.2 ± 2.9 years, 26% male. Before and after the course, two minutes of CCs, the following parameters have shown significant differences: the average total number of compressions (166 vs. 198, p = 0.0001),frequency (89 vs. 99 compressions/min, p = 0.0055) and percentage of correct position of the hands (51% vs. 87%, p < 0.0001).On the other hand, the percentage of CCs with adequate depth was 20% from 27% before and after the course, revealed no significant difference, p = 0.0580. CONCLUSION: The quality of CCs improved significantly after CPR training. However, the depth of CCs remained still insufficient even after training, which emphasizes the need of devices that can provide a quality feedback during CPR.


Assuntos
Humanos , Masculino , Feminino , Adulto , Massagem Cardíaca , Reanimação Cardiopulmonar/educação , Estudantes , Tutoria
5.
Rev. Col. Bras. Cir ; 37(1): 027-030, ene.-feb. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-554488

RESUMO

OBJETIVO: Testar a eficácia de equipamento de detecção gama intra-operatória (DGI) desenvolvido pelo IPEN (Brasil), em procedimentos de biópsia de linfonodo sentinela (BLS) no melanoma e no câncer de mama. MÉTODOS: Foram estudados 40 pacientes portadores de melanoma ou câncer de mama com indicação para realização de BLS.Todos pacientes foram submetidos à linfocintilografia e a BLS ocorreu entre 2 a 24 horas após a mesma. Concomitantemente à DGI, realizou-se o mapeamento linfático com corante vital. Foram feitas leituras com o equipamento convencional Neoprobe® 1500 e com o equipamento em teste (IPEN) dos valores de captação do sítio de injeção do radiofármaco, do LS in vivo e ex vivo e da captação de fundo. Foi registrado se o LS estava corado e se o cirurgião teve facilidade para encontrá-lo. Nos primeiros 20 pacientes utilizou-se o equipamento convencional e depois o de teste; nos outros 20, utilizou-se primeiro o equipamento em teste, com objetivo de verificar se o mesmo identificava primariamente o LS. RESULTADOS: Dos quarenta pacientes, 33 eram portadores de tumor de mama e sete de melanoma cutâneo; variação da idade: 21 a 68 anos (mediana= 46 anos); 35 mulheres e 5 homens. Em apenas um paciente o LS não foi encontrado, nem pela DGI nem pelo corante vital. Não houve diferença estatística entre as razões ex vivo/fundo obtidas com os dois equipamentos (p=0, 2583-ns). CONCLUSÃO: É possível realizar o procedimento de BLS com o equipamento brasileiro desenvolvido pelo IPEN, com facilidade e sem prejuízo para o paciente.


OBJECTIVE: To test the effectiveness of an intra-operative gamma detection Brazilian device (IPEN) on sentinel lymph node biopsy (SLNB) procedures. METHODS: Forty melanoma or breast cancer patients with indication for undergoing SLNB were studied. Lymphoscintigraphy was done 2 to 24 hours prior to surgery. Lymphatic mapping with vital dye and gamma detection were performed intraoperatively. For gamma detection Neoprobe ® 1500 was used followed by IPEN (equipment under test) in the first 20 patients and for the remaining half IPEN was used first to verify its ability to locate the sentinel node (SN). Measurements were taken from the radiopharmaceutical product injection site, from SN (in vivo and ex vivo) and from background. It was recorded if the SN was stained or not and if it was found easily by surgeon. RESULTS: There were 33 (82.5 percent) breast cancer and 7 (17.5 percent) melanoma patients. Ages varied from 21 to 68 year-old (median age of 46). Sex distribution was 35 (87.5 percent) women and 5 (12.5 percent) men. Sentinel node was found in all but one patient. There was no statistical difference between the reasons ex vivo/ background obtained with the measures of both equipments (p=0, 2583-ns). The SN was easily found by the surgeon with both devices. CONCLUSION: The SLNB was successfully performed using either equipment. It was possible to do SLNB with the Brazilian device developed by IPEN without prejudice for the patient.


Assuntos
Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Neoplasias da Mama/diagnóstico , Raios gama , Cuidados Intraoperatórios/instrumentação , Cuidados Intraoperatórios/métodos , Melanoma/patologia , Melanoma , Biópsia de Linfonodo Sentinela/métodos , Neoplasias Cutâneas/diagnóstico , Brasil , Neoplasias da Mama/patologia , Desenho de Equipamento , Estudos Prospectivos , Neoplasias Cutâneas/patologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA